替换电池规格参数

  • 电池型号: LI23S002A
  • 容量: 4500mAh
  • 电压: 11.1V
  • 电池类型: 锂离子(Li-ion)
  • 电芯: 高品质保证
  • 颜色: 黑色
  • 状态: 替换电池(100%全新,1年质保!)

可替换部件编号

  • LI23S002A
  • 022-000008-00
  • M05-010002-6
  • 115-018012-00

兼容的病人监护仪型号

  • 迈瑞 Mindray BeneView T5 生命体征监护仪
  • 迈瑞 Mindray BeneView T6 生命体征监护仪
  • 迈瑞 Mindray BeneView T8 生命体征监护仪
  • 迈瑞 Mindray BeneView N12 病人监护仪
  • 迈瑞 Mindray BeneView N15 病人监护仪
  • 迈瑞 Mindray BeneView N17 病人监护仪
  • 迈瑞 Mindray Passport 12 病人监护仪
  • 迈瑞 Mindray Passport 12m 病人监护仪
  • 迈瑞 Mindray Passport 17m 病人监护仪
  • 迈瑞 Mindray Accutorr 3 生命体征监护仪
  • 迈瑞 Mindray Accutorr 7 生命体征监护仪
  • 迈瑞 Mindray Passport 8 病人监护仪
  • 迈瑞 Mindray VS600 生命体征监护仪
  • 迈瑞 Mindray VS900 生命体征监护仪
  • 迈瑞 Mindray VS9 生命体征监护仪
  • 迈瑞 Mindray DPM6 病人监护仪
  • 迈瑞 Mindray DPM7 病人监护仪

产品特点

  • 医疗级可靠性: 4500mAh 大容量为迈瑞 BeneView、Passport、Accutorr、VS 及 DPM 系列病人监护仪提供稳定电力,确保在关键病患护理和医疗操作过程中持续运行。
  • OEM 级品质: 采用高品质锂离子电芯制造,符合或超越迈瑞原厂规格,确保医疗级应用的可靠性能与长期耐用性。
  • 广泛兼容性: 专为 Mindray BeneView T5/T6/T8、N12/N15/N17、Passport 8/12/12m/17m、Accutorr 3/7、VS600/VS900/VS9 及 DPM6/DPM7 监护仪设计,完美匹配,多设备通用。
  • 先进锂离子技术: 高品质锂离子电芯提供稳定输出电压、高效充放电循环,并支持数百次充放电周期,延长设备使用寿命。
  • 安装简便: 原厂电池直接替换设计,即插即用,减少设备停机时间,快速完成更换。
  • 全面安全保护: 内置过充、过放、短路及过热保护电路,确保使用安全,有效保护关键医疗监护设备。

为什么选择这款电池?

LI23S002A 替换电池是医院、诊所及医疗专业人员使用迈瑞 BeneView、Passport、Accutorr、VS 和 DPM 系列病人监护仪的理想电源解决方案。4500mAh 容量与 11.1V 输出电压,可为连续病人监护、生命体征监测、心电监护及重症护理应用提供稳定可靠的续航,确保关键时刻设备正常运行。

本电池兼容 Mindray BeneView T5/T6/T8、N12/N15/N17、Passport 8/12/12m/17m、Accutorr 3/7、VS600/VS900/VS9 及 DPM6/DPM7 监护仪,提供 1 年质保,并经过严格质量测试。非常适合医院、急诊科、重症监护室及需要可靠备用电源的医疗机构。

选择这款高性价比的医疗级替换电池,为关键医疗监护应用提供稳定可靠的电力保障,确保患者护理不中断。

查看更多相关电池

注意事项:

安全与合规
本产品在严格的质量控制标准下生产,符合 UN38.3、CE、RoHS 等国际安全要求。请遵循设备制造商的使用说明以确保安全使用。
专业安装建议
安装或更换操作应由经过培训的人员或具备资质的技术人员执行。
医疗用途免责声明
本电池作为兼容医疗设备的替换电源部件使用,不用于诊断、治疗、治愈或预防任何医疗疾病。
商标免责声明
所有品牌名称、商标及型号仅用于兼容性参考,其所有权归各自所有者所有。
重要提示
购买前请核实电池型号、电压及接口类型,以确认兼容性。如有疑问,请联系客服支持。

运输方式

配送方式 配送目的地 预计配送时间 运费 税费
USPS / DHL 美国 10–15个工作日 免费 免费
Canada Post 加拿大 10–15个工作日 免费 免费
Royal Mail / Yodel 英国 15–20个工作日 免费 免费
DHL 德国 15–20个工作日 免费 免费
La Poste 法国 15–20个工作日 免费 免费
Correios 墨西哥/西班牙/意大利 15–25个工作日 免费 免费
当地物流 东南亚 / 东亚 5–10个工作日 免费 免费
当地物流 欧洲其他地区 20–25个工作日 低至 $5.99 免费
当地物流 阿联酋 / 沙特阿拉伯 / 以色列 16–20个工作日 低至 $7.99 免费

📦 配送与物流追踪信息

需要更快的配送?我们提供本地仓储服务。 请访问我们的「本地配送」页面,查看可即时发货的商品。

1. 如何追踪您的包裹:
请根据您的目的地选择对应的追踪链接:

需要帮助?
如果您在上述网站上无法查找到包裹信息,请立即联系我们。

📧 邮箱:sales@batterymall.com / info@batterymall.com
📱 微信/WhatsApp:(+86) 198 6775 1872 / (+86) 191 2767 3310

🚚 预计配送时间

(1)从中国发货:

  • 至亚洲:5–20个工作日
  • 至北美洲:10–15个工作日
  • 至欧洲/南美洲:15–20个工作日

(2)从本地仓库发货:

  • 美国仓发货:3–5个工作日
  • 欧洲仓发货:2–10个工作日
  • 俄罗斯仓发货:3–5个工作日

请注意:具体到达时间取决于目的国家及海关处理情况。

⚠️ 税费及海关说明:

全球产品价格已包含关税(部分国家需提供税号)。具体运费请参照结算发票。若您的包裹被海关查验,需配合进行特殊处理。

支付方式

Paypal

paypal icon
通过 PayPal 付款,无需 PayPal 账户。PayPal 对买家安全且免费。
PayPal 账户:Payment@batterymall.com
账户名称:ShenZhen KingSener Science and Technology Co., Ltd

信用卡或借记卡

Credit Card icon
支持 VISA、MasterCard、American Express、Maestro & Laser Card、APPLE Pay 等。
PayPal 不会将您的财务信息共享给我们。

微信支付

wechat pay icon
目前仅支持扫码付款。请联系微信客服,并在微信 App 中扫描二维码完成支付。

Google Pay

Google Pay
使用 Google Pay 付款,更方便快捷。

Apple Pay

Apple Pay

Q&A

Medical Equipment Battery Guide

  • How often should medical device batteries be replaced?
    Medical device battery replacement intervals depend on equipment type and usage frequency. We recommend the following guidelines:

    General Replacement Schedule:
    • Replace every 1-2 years, or after 300-500 charge/discharge cycles
    • Regardless of apparent battery health

    High-Risk Equipment (Strict OEM Compliance Required):
    • Life-support devices (ventilators, ECMO machines)
    • Emergency equipment (defibrillators, cardiac monitors)
    • Anesthesia delivery systems
    • Infusion pumps

    ⚠️ Critical Warning: For medical equipment directly affecting patient lives, you MUST follow the OEM recommended battery replacement schedule. Even if the battery passes functional tests, scheduled replacement prevents power failures during critical moments.
  • Are KingSener medical batteries fully certified?
    Yes. KingSener medical replacement batteries meet multiple international certifications:

    Core Certifications:
    • ISO 13485 — Medical Device Quality Management System
    • IEC 62133 — Safety for Secondary Lithium Cells
    • UL94 V-0 — Flame-Retardant Housing Rating
    • CE Mark — EU Market Access
    • RoHS Compliant — Hazardous Substance Restriction

    Why These Matter:
    • ISO 13485 ensures full batch traceability under controlled quality management
    • IEC 62133 validates battery safety under extreme conditions (overcharge, short circuit, crush)
    • UL94 V-0 prevents fire spread in sealed medical equipment enclosures

    💡 Note: Our products are positioned as replacement batteries for repair and maintenance. For OEM new equipment manufacturing, contact us for customized compliance solutions.
  • How should I store backup medical batteries for emergencies?
    Proper storage directly affects battery lifespan and emergency reliability:

    Standard Storage Conditions:
    Charge State: 40%-50% (partial charge — full charge accelerates aging)
    Temperature: 15°C - 25°C / 59°F - 77°F (high heat speeds capacity loss)
    Humidity: 30% - 50% (excess moisture causes terminal corrosion)
    Avoid: Direct sunlight, high humidity, heat sources

    Mandatory Maintenance Schedule:
    • Every 3-6 months: Check voltage, inspect for swelling, check connector corrosion
    • Every 6 months: Perform a full charge/discharge cycle to maintain cell activity
    • Annually: Assess whether replacement is needed (even before cycle limit)

    🏥 Hospitals/Clinics: Equip emergency vehicles and resuscitation rooms with dedicated battery spare kits. Record each battery's "last inspection date" and "scheduled replacement date."
  • How do I calibrate a new patient monitor battery?
    Battery calibration ensures accurate remaining-runtime display. Perform every 3-6 months:

    Step 1 — Full Charge:
    Insert battery and charge to 100% using the original charger. Do not use the device during charging.

    Step 2 — Full Discharge:
    Unplug the charger. Run the monitor until it automatically powers down. Allow the device to rest for 30 minutes.

    Step 3 — Second Full Charge:
    Reconnect the original charger. Charge to 100% without interruption. Do not use the device until charging completes.

    Post-Calibration:
    Observe whether the battery display is stable. Record this calibration date and set a reminder for the next calibration.

    ⚠️ Compatible Brands: Philips IntelliVue, GE CARESCAPE, Mindray, NIHON KOHDEN, and most other patient monitor brands. For brand-specific procedures, refer to the device user manual.
  • Will the equipment recognize the replacement battery?
    Yes. KingSener medical replacement batteries are specifically designed for perfect OEM compatibility:

    1. Smart BMS Chips:
    Each battery includes an integrated Battery Management System (BMS) chip that communicates precisely with the device's host system — preventing "unrecognized battery" errors and ensuring accurate power readings.

    2. OEM Specification Matching:
    Identical voltage, capacity, and connector definitions. Plug-and-play — no device reconfiguration required.

    3. Compatibility Testing:
    All batteries undergo multi-brand device compatibility testing before shipping. Our compatibility database is continuously updated.

    Common Questions:
    • "Non-original battery" warning? → Normal and does not affect functionality
    • Battery percentage inaccurate? → Perform calibration (see above)
    • Device won't power on? → Check contacts and charger; contact customer service if needed