NKB-301V-12V-2800mAh-Medical-Battery

NKB-301V Battery Pack For NIHON KOHDEN TEC-7721 TEC-7621C TEC-7631C TEC-5500 ECG-1350P 1350C 2350 ECG-7600 7700 TEC-5600 TEC-7621K Defibrillator Battery

¥427.00 CNY
Sale price ¥427.00 CNY Regular price ¥498.00 CNY
Skip to product information
NKB-301V-12V-2800mAh-Medical-Battery

NKB-301V Battery Pack For NIHON KOHDEN TEC-7721 TEC-7621C TEC-7631C TEC-5500 ECG-1350P 1350C 2350 ECG-7600 7700 TEC-5600 TEC-7621K Defibrillator Battery

¥427.00 CNY
Sale price ¥427.00 CNY Regular price ¥498.00 CNY
In stock
Shipping location: China Warehouse
 

Products related to this item

Product Overview

Premium NKB-301V replacement battery specifically designed for NIHON KOHDEN ECG and defibrillator medical equipment. This high-capacity 2800mAh NiMH battery delivers reliable power for critical medical monitoring and emergency care applications.

Technical Specifications

  • Battery Model: NKB-301V
  • Voltage: 12V
  • Capacity: 2800mAh (High Capacity)
  • Battery Type: Premium NiMH
  • Color: White
  • Condition: Brand New (100% New, 1-year warranty)
  • Certification: Medical device quality standards

Compatible Part Numbers

  • NKB-301V
  • Typ X065

Compatible NIHON KOHDEN Medical Equipment

  • ECG Series: ECG-1350P, ECG-1350C, ECG-2350, ECG-7600, ECG-7700
  • TEC Series: TEC-5500, TEC-5521, TEC-5531, TEC-5600, TEC-7621K, TEC-7621C, TEC-7631C, TEC-7631, TEC-7721, TEC-7731

Key Features

  • 2800mAh high capacity for extended operation time
  • Perfect compatibility with NIHON KOHDEN medical devices
  • Medical-grade reliability for critical care applications
  • Built-in safety protection for patient safety
  • Easy installation with no modifications required
  • 1-year manufacturer warranty for peace of mind

Installation & Quality

This replacement battery is designed for easy installation in your NIHON KOHDEN ECG or defibrillator equipment. Each battery undergoes rigorous quality testing to ensure it meets medical device standards for performance and safety.

Notice: Not all compatible models are listed. Please verify your battery model number before purchase or contact us for compatibility assistance.

Note:

Safety & Compliance
Manufactured under strict quality control standards. Complies with international safety requirements such as UN38.3, CE, and RoHS. Follow the device manufacturer’s instructions for safe use.
Professional Installation Recommendation
Installation or replacement should be performed by trained personnel or qualified technicians.
Medical Use Disclaimer
This battery is intended as a replacement power component for compatible medical devices. It is not intended to diagnose, treat, cure, or prevent any medical condition.
Trademark Disclaimer
All brand names, trademarks, and model numbers are used for compatibility reference only and remain the property of their respective owners.
Important Notice
Please verify the battery model, voltage, and connector type before purchasing to ensure compatibility. Contact support if unsure.

Shipping Methods

Shipping Methods Ship To Est. Delivery Time Shipping Cost Taxes & Fees
USPS / DHL United States 10-15 business days Free Free
Canada Post Canada 10-15 business days Free Free
Royal Mail / Yodel United Kingdom 15-20 business days Free Free
DHL Germany 15-20 business days Free Free
La Poste France 15-20 business days Free Free
Correios Mexico/Spain/IT 15-25 business days Free Free
Local Carriers SE Asia / East Asia 5-10 business days Free Free
Local Carriers Rest of Europe 20-25 business days From $5.99 Free
Local Carriers UAE / Saudi Arabia / Israel 16-20 business days From $7.99 Free

📦 Shipping & Tracking Information

Looking for faster shipping? We offer local warehousing services. Please visit our "Local Delivery" page for items available for immediate dispatch.

1. How to Track Your Package:
Please choose the tracking link that corresponds to your destination:

Need Help?
If you cannot find your package on any of the above websites, please contact us immediately.

📧 Email: sales@batterymall.com / info@batterymall.com
📱 WeChat/WhatsApp: (+86) 198 6775 1872 / (+86) 191 2767 3310

🚚 Estimated Delivery Time

(1) Shipping from China:

  • To Asia: 5-20 business days
  • To North America: 10-15 business days
  • To Europe/South America: 15-20 business days

(2) Shipping from Local Warehouses:

  • From US Warehouse: 3-5 business days
  • From European Warehouse: 2-10 business days
  • From Russian Warehouse: 3-5 business days

Please note: Exact arrival times depend on the specific country and customs processing.

⚠️ Tax & Customs Information:

Global product prices include customs duties (some countries require a tax ID). Please refer to the settlement invoice for specific shipping costs. Special handling is required if your package is inspected.

Payment Methods

Paypal

paypal icon
Payments by PayPal, no PayPal account required. Paypal is safe and free for buyers.
PayPal account: Payment@batterymall.com
Account Name: ShenZhen KingSener Science and Technology Co., Ltd

Credit or debit card

Credit Card icon
VISA, MasterCard, the United States n Express,Maestro & Laser Card, APPLE Pay,etc.
PayPal never shares your financial information with us.

WeChat Pay

wechat pay icon
Currently only supports QR code payment. Please contact WeChat customer service and go to WeChat App to scan the QR code to complete the payment.

Google Pay

Google Pay
Pay with Google Pay, which is more convenient and faster.

Apple Pay

Apple Pay
If you use an Apple device, you can use Apple Pay to pay, which is more convenient and faster.

Bank Transfer

If you cannot use the above payment methods and the order amount exceeds HK$2000, please contact our customer service to obtain your bank account and pay via bank transfer.

Q&A

Medical Equipment Battery Guide

  • How often should medical device batteries be replaced?
    Medical device battery replacement intervals depend on equipment type and usage frequency. We recommend the following guidelines:

    General Replacement Schedule:
    • Replace every 1-2 years, or after 300-500 charge/discharge cycles
    • Regardless of apparent battery health

    High-Risk Equipment (Strict OEM Compliance Required):
    • Life-support devices (ventilators, ECMO machines)
    • Emergency equipment (defibrillators, cardiac monitors)
    • Anesthesia delivery systems
    • Infusion pumps

    ⚠️ Critical Warning: For medical equipment directly affecting patient lives, you MUST follow the OEM recommended battery replacement schedule. Even if the battery passes functional tests, scheduled replacement prevents power failures during critical moments.
  • Are KingSener medical batteries fully certified?
    Yes. KingSener medical replacement batteries meet multiple international certifications:

    Core Certifications:
    • ISO 13485 — Medical Device Quality Management System
    • IEC 62133 — Safety for Secondary Lithium Cells
    • UL94 V-0 — Flame-Retardant Housing Rating
    • CE Mark — EU Market Access
    • RoHS Compliant — Hazardous Substance Restriction

    Why These Matter:
    • ISO 13485 ensures full batch traceability under controlled quality management
    • IEC 62133 validates battery safety under extreme conditions (overcharge, short circuit, crush)
    • UL94 V-0 prevents fire spread in sealed medical equipment enclosures

    💡 Note: Our products are positioned as replacement batteries for repair and maintenance. For OEM new equipment manufacturing, contact us for customized compliance solutions.
  • How should I store backup medical batteries for emergencies?
    Proper storage directly affects battery lifespan and emergency reliability:

    Standard Storage Conditions:
    Charge State: 40%-50% (partial charge — full charge accelerates aging)
    Temperature: 15°C - 25°C / 59°F - 77°F (high heat speeds capacity loss)
    Humidity: 30% - 50% (excess moisture causes terminal corrosion)
    Avoid: Direct sunlight, high humidity, heat sources

    Mandatory Maintenance Schedule:
    • Every 3-6 months: Check voltage, inspect for swelling, check connector corrosion
    • Every 6 months: Perform a full charge/discharge cycle to maintain cell activity
    • Annually: Assess whether replacement is needed (even before cycle limit)

    🏥 Hospitals/Clinics: Equip emergency vehicles and resuscitation rooms with dedicated battery spare kits. Record each battery's "last inspection date" and "scheduled replacement date."
  • How do I calibrate a new patient monitor battery?
    Battery calibration ensures accurate remaining-runtime display. Perform every 3-6 months:

    Step 1 — Full Charge:
    Insert battery and charge to 100% using the original charger. Do not use the device during charging.

    Step 2 — Full Discharge:
    Unplug the charger. Run the monitor until it automatically powers down. Allow the device to rest for 30 minutes.

    Step 3 — Second Full Charge:
    Reconnect the original charger. Charge to 100% without interruption. Do not use the device until charging completes.

    Post-Calibration:
    Observe whether the battery display is stable. Record this calibration date and set a reminder for the next calibration.

    ⚠️ Compatible Brands: Philips IntelliVue, GE CARESCAPE, Mindray, NIHON KOHDEN, and most other patient monitor brands. For brand-specific procedures, refer to the device user manual.
  • Will the equipment recognize the replacement battery?
    Yes. KingSener medical replacement batteries are specifically designed for perfect OEM compatibility:

    1. Smart BMS Chips:
    Each battery includes an integrated Battery Management System (BMS) chip that communicates precisely with the device's host system — preventing "unrecognized battery" errors and ensuring accurate power readings.

    2. OEM Specification Matching:
    Identical voltage, capacity, and connector definitions. Plug-and-play — no device reconfiguration required.

    3. Compatibility Testing:
    All batteries undergo multi-brand device compatibility testing before shipping. Our compatibility database is continuously updated.

    Common Questions:
    • "Non-original battery" warning? → Normal and does not affect functionality
    • Battery percentage inaccurate? → Perform calibration (see above)
    • Device won't power on? → Check contacts and charger; contact customer service if needed

Hot categories

    You may also like