{"product_id":"10h-e200aa-replacement-battery-for-bexel-msc-v110-ecg-patient-monitor","title":"10H-E200AA Battery 12V 2000mAh Ni-MH for BEXEL MSC-V110 ECG Patient Monitor Replacement","description":"\u003cdiv class=\"product-desc\"\u003e\n\u003ch2\u003e12V 2000mAh Ni-MH Replacement Battery for BEXEL MSC-V110 ECG Patient Monitor\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003e10H-E200AA\u003c\/strong\u003e is a 12V 2000mAh Ni-MH replacement battery engineered for the \u003cstrong\u003eBEXEL MSC-V110\u003c\/strong\u003e ECG patient monitor. BEXEL is a leading Korean medical device manufacturer, and the MSC-V110 is widely deployed in hospitals across Asia and the Middle East for continuous cardiac monitoring in ICU, CCU, and general ward settings. This replacement battery restores full cordless runtime at a fraction of OEM pricing.\u003c\/p\u003e\n\u003cp\u003eBuilt with 10 individual Ni-MH cells in a rugged blue housing, this battery is rated for \u003cstrong\u003e500-1000 charge\/discharge cycles\u003c\/strong\u003e — providing years of dependable service under normal clinical use. Each unit is fully tested before shipment.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExact Fit for BEXEL MSC-V110:\u003c\/strong\u003e Drop-in replacement — no modifications needed. Form factor matches the OEM 10H-E200AA battery precisely.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e500-1000 Cycle Lifespan:\u003c\/strong\u003e Long service life minimizes the frequency of battery replacements, reducing total cost of ownership for hospital biomedical departments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNi-MH Reliability:\u003c\/strong\u003e Nickel-metal hydride chemistry ensures stable voltage output throughout the discharge cycle, maintaining accurate ECG waveform display without signal artifacts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10-Cell Configuration:\u003c\/strong\u003e Ten individual Ni-MH cells deliver consistent 12V output with balanced discharge across all cells.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRugged Construction:\u003c\/strong\u003e Impact-resistant ABS housing protects internal cells from daily handling in busy clinical environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Model:\u003c\/strong\u003e 10H-E200AA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 12V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacity:\u003c\/strong\u003e 2000mAh (24Wh)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChemistry:\u003c\/strong\u003e Ni-MH (Nickel-Metal Hydride)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCell Configuration:\u003c\/strong\u003e 10 Cells\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCycle Life:\u003c\/strong\u003e 500-1000 cycles\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 105 × 28 × 28 mm (4.13 × 1.10 × 1.10 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 300g (0.66 lbs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e Blue\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12 Months\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondition:\u003c\/strong\u003e Brand New\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eCompatible Equipment\u003c\/h3\u003e\n\u003cul class=\"desc-tb-flex-3\"\u003e\n\u003cli\u003eBEXEL MSC-V110 ECG Patient Monitor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eCompatible OEM Part Numbers\u003c\/h3\u003e\n\u003cul class=\"desc-tb-flex-2\"\u003e\n\u003cli\u003e10H-E200AA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eSafety Protection System\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvercharge Protection:\u003c\/strong\u003e Automatically terminates charging when voltage reaches safe threshold.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOver-Discharge Protection:\u003c\/strong\u003e Prevents deep discharge that permanently damages Ni-MH cell capacity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort Circuit Protection:\u003c\/strong\u003e Integrated fuse isolates the battery instantly under fault conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Protection:\u003c\/strong\u003e Internal temperature sensor prevents overheating during charge and discharge.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCell Balancing:\u003c\/strong\u003e Individual cell monitoring ensures all 10 cells discharge evenly for maximum runtime and longevity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eCertifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Certified:\u003c\/strong\u003e Compliant with European Union safety and EMC standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliant:\u003c\/strong\u003e Free from restricted hazardous substances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eISO 9001:\u003c\/strong\u003e Manufactured in a certified quality management facility.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eAbout the BEXEL MSC-V110 ECG Monitor\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBEXEL\u003c\/strong\u003e is a South Korean medical device manufacturer specializing in patient monitoring systems. The \u003cstrong\u003eMSC-V110\u003c\/strong\u003e is a portable ECG monitor used for continuous cardiac rhythm observation in intensive care units (ICU), coronary care units (CCU), emergency departments, and general wards across Asia-Pacific and Middle Eastern hospitals.\u003c\/p\u003e\n\u003cp\u003eLike all portable patient monitors, the MSC-V110 relies on its internal battery for uninterrupted operation during patient transport, bed transfers, or brief power interruptions. A degraded battery compromises the monitor's portability and can lead to unexpected shutdowns — potentially missing critical arrhythmia events. Regular battery replacement every 2-3 years is standard biomedical engineering practice for this equipment class.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Will this battery fit my BEXEL MSC-V110?\u003c\/strong\u003e\u003cbr\u003eA: Yes. The 10H-E200AA is the exact replacement battery for the BEXEL MSC-V110 ECG monitor. Please verify the model number on your existing battery before ordering.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How long does a full charge last?\u003c\/strong\u003e\u003cbr\u003eA: A fully charged 2000mAh battery typically provides several hours of continuous ECG monitoring, depending on screen brightness, alarm frequency, and NIBP measurement cycles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How many charge cycles can I expect?\u003c\/strong\u003e\u003cbr\u003eA: This battery is rated for 500-1000 charge\/discharge cycles under normal use conditions. At one cycle per day, that translates to roughly 1.5-3 years of service.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Do I need to calibrate the battery after installation?\u003c\/strong\u003e\u003cbr\u003eA: No calibration is required. Simply insert the battery, charge fully, and the monitor will display accurate battery status.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is there a warranty?\u003c\/strong\u003e\u003cbr\u003eA: Yes, 12-month full replacement warranty against manufacturing defects.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Maintenance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation:\u003c\/strong\u003e Power off the MSC-V110 monitor and disconnect from AC mains. Open the battery compartment (typically on the rear panel), remove the old battery, insert the new 10H-E200AA ensuring the connector is firmly seated, close the compartment, and power on to verify.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirst Charge:\u003c\/strong\u003e Charge fully (4-6 hours) before first clinical use. The monitor's battery indicator will show charging progress.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoutine Check:\u003c\/strong\u003e Run a full discharge test every 6 months. Set the monitor to battery power and record the runtime. Log results in the equipment maintenance file.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage:\u003c\/strong\u003e Store spare batteries at 40-60% charge in a cool, dry environment (15-25°C). Avoid storage at full charge or fully depleted.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisposal:\u003c\/strong\u003e Recycle through approved Ni-MH battery recycling programs. Do not dispose of in general waste.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Bexel","offers":[{"title":"Default Title","offer_id":46316012175532,"sku":"10H-E200AA-12V-2000mAh","price":376.8,"currency_code":"HKD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0429\/2047\/6834\/files\/Bexel-10H-E200AA-12V-2000mAh-Medical-Battery-1.jpg?v=1779931507","url":"https:\/\/www.batterymall.com\/zh-tw\/products\/10h-e200aa-replacement-battery-for-bexel-msc-v110-ecg-patient-monitor","provider":"BatteryMall.com","version":"1.0","type":"link"}