{"product_id":"420315-001-replacement-battery-ge-eagle-monitor-4000","title":"420315-001 12V 3000mAh Ni-MH Replacement Battery for GE Eagle Monitor 3000 4000 | 120184 BATT\/110184 OM11116","description":"\u003ch2 class=\"desc-tb-title-2\"\u003eProduct Specification\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Type:\u003c\/strong\u003e Ni-MH (Nickel-Metal Hydride)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 12V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacity:\u003c\/strong\u003e 3000mAh \/ 36Wh\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCell Configuration:\u003c\/strong\u003e 10 x SC Ni-MH Cells\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 254 x 50 x 27.5mm (10.0 x 1.97 x 1.08 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 480g (1.06 lbs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e Blue\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCycle Life:\u003c\/strong\u003e 500+ Charge\/Discharge Cycles\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1 Year\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCompatible Devices\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGE Eagle Monitor 3000 Patient Monitor\u003c\/li\u003e\n\u003cli\u003eGE Eagle Monitor 4000 Patient Monitor\u003c\/li\u003e\n\u003cli\u003eMarquette Electronics Eagle 4000\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eReplacement Part Numbers\u003c\/h2\u003e\n\u003cul class=\"desc-tb-flex-2\"\u003e\n\u003cli\u003e420315-001\u003c\/li\u003e\n\u003cli\u003e120184\u003c\/li\u003e\n\u003cli\u003eBATT\/110184\u003c\/li\u003e\n\u003cli\u003eOM11116\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Capacity Ni-MH Chemistry:\u003c\/strong\u003e 3000mAh provides extended monitoring runtime, keeping GE Eagle monitors operational during patient transport and in areas without immediate AC power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero Memory Effect:\u003c\/strong\u003e Unlike older Ni-Cd batteries, this Ni-MH battery can be partially discharged and recharged without capacity degradation — ideal for clinical environments where batteries are frequently topped up between uses.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision-Molded Housing:\u003c\/strong\u003e Exact OEM dimensions (254 x 50 x 27.5mm) ensure seamless fit in GE Eagle Monitor battery compartments with secure locking mechanism.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong Service Life:\u003c\/strong\u003e Rated for 500+ charge\/discharge cycles, delivering reliable performance across years of daily clinical use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Self-Discharge:\u003c\/strong\u003e Retains up to 85% charge after 30 days of storage, ensuring readiness for emergency deployment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSafety Protection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOver-Charge Protection:\u003c\/strong\u003e Automatically terminates charging when voltage exceeds safe threshold, preventing cell damage and thermal runaway.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOver-Discharge Protection:\u003c\/strong\u003e Cuts off output when voltage drops below minimum safe level to prevent irreversible cell degradation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOver-Current Protection:\u003c\/strong\u003e Limits discharge current during high-load conditions to protect both battery and connected monitor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-Circuit Protection:\u003c\/strong\u003e Instantaneous circuit cutoff in the event of a short, eliminating fire and explosion risk.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Protection:\u003c\/strong\u003e Built-in PTC thermistor continuously monitors internal temperature; suspends operation if overheating is detected.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCell Balancing:\u003c\/strong\u003e Individual cell voltage monitoring ensures uniform charge\/discharge across all 10 Ni-MH cells, maximizing pack lifespan.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCertifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Certified\u003c\/strong\u003e — Complies with EU health, safety, and environmental protection standards for medical electrical equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliant\u003c\/strong\u003e — Free from lead, mercury, cadmium, and other restricted hazardous substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUN38.3 Tested\u003c\/strong\u003e — Passes UN Manual of Tests and Criteria for safe transport of batteries\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eISO 9001\u003c\/strong\u003e — Manufactured in an ISO 9001 certified facility with rigorous quality management systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMSDS Available\u003c\/strong\u003e — Material Safety Data Sheet provided upon request for hospital procurement compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAbout the GE Eagle Monitor Series\u003c\/h3\u003e\n\u003cp\u003eThe GE Eagle Monitor 3000 and 4000 are versatile multi-parameter patient monitoring systems deployed in hospitals, emergency departments, intensive care units, and ambulatory surgical centers worldwide. These monitors provide real-time tracking of vital signs including ECG, SpO₂, NIBP, temperature, and respiratory rate — making them essential tools for continuous patient surveillance. The 420315-001 Ni-MH battery serves as the primary portable power source, enabling uninterrupted monitoring during intra-hospital transport, emergency response, and in clinical areas without immediate AC power access. A reliable replacement battery is mission-critical for maintaining continuous patient safety and clinical workflow efficiency.\u003c\/p\u003e\n\u003ch3\u003eInstallation \u0026amp; Maintenance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInitial Charge:\u003c\/strong\u003e Charge the battery for 14-16 hours before first use to fully activate all 10 Ni-MH cells.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharging:\u003c\/strong\u003e Use only GE-approved or compatible chargers designed for 12V Ni-MH medical battery packs. Do not use lithium-ion chargers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage:\u003c\/strong\u003e Store in a cool, dry environment (15-25°C \/ 59-77°F) away from direct sunlight. For extended storage, charge to 40-60% and recharge every 3 months.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCleaning:\u003c\/strong\u003e Wipe battery contacts with a dry, lint-free cloth. Never use liquid cleaners, alcohol, or solvents on battery terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplacement Indicator:\u003c\/strong\u003e Replace when runtime drops below 70% of original capacity, or the Eagle Monitor displays persistent low-battery warnings shortly after a full charge cycle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisposal:\u003c\/strong\u003e Dispose of at designated Ni-MH battery recycling facilities in accordance with local regulations. Never incinerate or dispose of in general waste.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is this an original GE Healthcare battery?\u003c\/strong\u003e\u003cbr\u003eA: No, this is a high-quality compatible replacement manufactured to meet or exceed OEM specifications. It is not manufactured by or affiliated with GE Healthcare.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Will this fit both Eagle 3000 and Eagle 4000 monitors?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the battery compartment is identical across both models. This replacement battery fits Eagle Monitor 3000, Eagle Monitor 4000, and Marquette Electronics Eagle 4000.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How long does the battery last on a full charge?\u003c\/strong\u003e\u003cbr\u003eA: Runtime depends on monitor configuration. Under typical monitoring (ECG + SpO₂ + NIBP every 15 min), expect approximately 4-6 hours of continuous portable operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I charge the battery while the monitor is running on AC power?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the GE Eagle Monitor supports pass-through charging — the battery charges automatically while the monitor operates on AC mains power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How is this different from lithium-ion replacements?\u003c\/strong\u003e\u003cbr\u003eA: Ni-MH chemistry offers superior tolerance to partial-state-of-charge cycling (common in clinical settings), zero fire\/thermal runaway risk compared to Li-ion, and easier regulatory compliance for air transport. This battery matches the original OEM chemistry specification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What certifications does this battery carry?\u003c\/strong\u003e\u003cbr\u003eA: CE, RoHS, UN38.3, and MSDS. Manufactured in an ISO 9001 certified facility.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":46316012306604,"sku":"420315-001-12V-3000mAh","price":70.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0429\/2047\/6834\/files\/GE-420315-001-12V-3000mAh-Medical-Battery-1.png?v=1779931090","url":"https:\/\/www.batterymall.com\/en-it\/products\/420315-001-replacement-battery-ge-eagle-monitor-4000","provider":"BatteryMall.com","version":"1.0","type":"link"}